Data centre energy management checklist

This is a data centre energy management checklist from the Lawrence Berkeley National Laboratory.

  1. Mechanical: Airflow Management — The efficiency and effectiveness of a datacenter conditioning system is heavily influenced by the path, temperature and quantity of cooling air delivered to the IT equipment and waste hot air removed from the equipment.
    1. Eliminate mixing and recirculation of hot equipment exhaust air
      1. Hot aisle/Cold aisle.
      2. Rigid enclosures
      3. Flexible strip curtains
      4. Blank unused rack positions
      5. Design for IT airflow configuration
      6. Select racks with good internal airflow
    2. Maximize return air temperature by supplying air directly to the loads
      1. Use appropriate diffusers
      2. Position supply and returns to minimize mixing and short circuiting
      3. Minimize air Leaks in raised floor systems
      4. Optimize location of computer room air conditioners
      5. Provide adequately sized return plenum or ceiling height
      6. Provide adequately sized supply
      7. Use an appropriate pressure in underfloor supply plenums
  1. Mechanical: Air Handler Systems — The air handler fan is typically the second largest energy use in the mechanical system, and can even exceed the energy use of the cooling plant in some cases. Optimizing the air handler system for datacenter use, as opposed to relying on traditional air handler design rules developed over years of office system design, is essential to achieve an efficient and cost effective system.
    1. Minimize fan power requirements
      1. Low pressure drop system design
      2. Use redundant air handler capacity in normal operation
    2. Use an optimized airside economizer
      1. Implement an airside economizer
      2. Design for medium temperature air
      3. Control to avoid unnecessary humidity loads
    3. Use large centralized air handlers
      1. Use load diversity to minimize fan power use
      2. Optimize air handler for fan efficiency and low pressure drop
      3. Configure redundancy to reduce fan power use in normal operation
      4. Use premium efficiency motors and fans
      5. Control volume by variable speed drive on fans based on space temperature
  1. Mechanical: Humidification — Humidification specifications and systems have often been found to be excessive and/or wasteful in datacenter facilities. A careful, site specific design approach to these energy-intensive systems is usually needed to avoid energy waste.
    1. Design system to actual equipment requirements
      1. Use widest suitable humidity control band
      2. Specify humidity sensor calibration schedule
      3. Provide appropriate sensor redundancy
      4. Control humidity with dedicated outdoor air unit
    2. Eliminate over humidification and/or dehumidification
      1. Ensure proper economizer lockout
      2. Maintain coil temperature above 55F
      3. Centralize humidity control
    3. Use efficient humidification technology
      1. Use waste return air heat to humidify
      2. Use adiabatic humidifiers for humidity and evaporative cooling
      3. Use lower power humidification technology
  1. Mechanical: Plant Optimization — When a chilled water plant is used, all the standard design best practices apply, with a few additions. The unusual nature of a datacenter load, which is mostly independent of outside air temperature and solar loads, makes free cooling very attractive and increases the importance of efficiency over first cost. Also, the typical level of redundancy and reliability can influence the value of various design options.
    1. Maximize the chiller system efficiency
      1. Select chiller for high efficiency
      2. Implement an aggressive condenser water reset
      3. Minimize tower fan power and size towers for close approach
      4. Use free cooling / waterside economization
      5. Use a medium temperature chilled water loop
      6. Use primary only variable flow chilled water pumping
      7. Consider thermal storage
      8. Monitor system efficiency
      9. Rightsize the cooling plant
  1. IT Equipment: Selection — The IT equipment is the reason for the facility. Increasingly, there are reasonable opportunities to increase the efficiency of IT equipment, reducing the need for mechanical infrastructure and ongoing energy use directly at the load level through the selection of IT equipment.
    1. Specify efficient server equipment
      1. Specify high efficiency power supplies
      2. Consider equipment power consumption in specifications
    2. Use cooled equipment racks
      1. Use equipment racks with integral coil
      2. Consider direct liquid cooling
  1. Electrical Infrastructure — Protection from power loss is a common characteristic of datacenter facilities. Such protection comes at a significant first cost price, and also carries a continuous power usage cost that can be reduced through careful design and selection.
    1. Design UPS system for efficiency
      1. Maximize unit loading
    2. Select most efficient UPS possible
      1. Specify minimum unit efficiency at expected load points
      2. Evaluate UPS technologies for most efficient
      3. Do not overspecify power conditioning requirements
    3. Use self-generation for large installation
      1. Eliminate standby generator
      2. Recover waste heat for local heating uses
      3. Recover waste heat for datacenter cooling use
      4. Eliminate UPS systems
  1. Lighting — Datacenters are typically lightly occupied. While lighting is a small portion of the total power usage of a datacenter, it can be often be safely reduced through mature, inexpensive technologies and designs.
    1. Use active sensors to shutoff lights when datacenter is unoccupied
      1. Occupancy sensors
    2. Design light circuiting and switching to allow for greater manual control
      1. Bi-Level lighting
      2. Task lighting
  1. Commissioning and Retrocommissioning — An efficient datacenter not only requires a reliable and efficient design, it also requires proper construction and operation of the space. Commissioning is a methodical and thorough process to ensure the systems are installed and operating correctly in all aspects, including efficiency.
    1. Engage additional design expertise for review and guidance.
      1. Perform a peer review
      2. Engage a commissioning agent
    2. Perform system commissioning
      1. Document testing of all equipment and control sequences
      2. Measure equipment energy efficiency onsite
      3. Provide appropriate budget and scheduling for commissioning
      4. Perform full operational testing of all equipment
    3. Perform retrocommissioning
      1. Perform a full retrocommissioning
      2. Recalibrate all control sensors
      3. Where appropriate, install efficiency monitoring equipment

Comments

Popular posts from this blog

easywall - Web interface for easy use of the IPTables firewall on Linux systems written in Python3.

Firewalls are becoming increasingly important in today’s world. Hackers and automated scripts are constantly trying to invade your system and use it for Bitcoin mining, botnets or other things. To prevent these attacks, you can use a firewall on your system. IPTables is the strongest firewall in Linux because it can filter packets in the kernel before they reach the application. Using IPTables is not very easy for Linux beginners. We have created easywall - the simple IPTables web interface . The focus of the software is on easy installation and use. Access this neat software over on github: easywall

No Scrubs: The Architecture That Made Unmetered Mitigation Possible

When building a DDoS mitigation service it’s incredibly tempting to think that the solution is scrubbing centers or scrubbing servers. I, too, thought that was a good idea in the beginning, but experience has shown that there are serious pitfalls to this approach. Read the post of at Cloudflare's blog: N o Scrubs: The Architecture That Made Unmetered Mitigation Possible

Should You Buy A UniFi Dream Machine, USG, USG Pro, or Dream Machine Pro?